Wondcon 610F Infant Incubator
Wondcon 610F
Accuracy and durability,Mindry quality,competitive price!
PRODUCT DETAILS
Introduction
Two control modes: Air mode and Baby mode controlled by micro-computer
The information can be stored, checked and indicated by the LCD display screen
Humidity and Oxygen concentration level display and servo control system
“>37C” temperature set function
The air circulation system with outlet in both front and back
X-ray cassette under the bassinet
Embedded integrated sensor module, integrated water reservoir in the shape of drawer
Inclination of bassinet is adjustable
The height of whole unit can be adjusted
Multiple failure alarm indications
RS-232 connector for data output
Low noise DC motor
Standard Configuration
Hood, Main body, Vertical height adjustment stand (VHA stand), Controller, I.V. Pole and Shelf.
Optional Configuration
Weighing system, Monitor shelf and Disposable skin temperature sensor.
Product Packaging
Package: Main body and Cabinet are packed into two cartons
Dimension (Main body): 1110mm x 710mm x 888mm
(Cabinet): 1029mm x 697mm x 826mm
Gross Weight (Main body): 70Kg
(Cabinet): 80Kg
Environmental temperature
Operating range: 20°C -30°C(Set temperature should be 3CC higher than the environment temperature)
Ambient air velocity: <0.3m/s
Specification
Power supply: AC220V-230V/50Hz or AC110-120V/50-60HZ, 1300VA Control Mode: Air mode and Baby mode controlled by microcomputer Air temperature control range: 25°C-37°C(override mode37°C-39°c ) Baby temperature control range: 34°C-37°C (override mode 37°C-38°C) Accuracy of skin temperature sensor: ± 0.2°C The temperature fluctuation range between incubator temperature and average incubator temperature (under stable temperature condition): ≦O.5°C Temperature uniformity:≦0.8 °C (mattress is on the horizontal position) Inclination of the bassinet: ±8° Noise inside hood: ≦45dB(A) Failure alarm: over-temperature alarm, temperature deviation alarm, sensor alarm, motor fan failed alarm, power failure alarm, sensor box position alarm, tank position alarm, system alarm and so on. Humidity display range: 0%RH〜99%RH Humidity control range: 0%RH〜90%RH Accuracy Of humidity display:± 5%RH(environment temperature is 25°C, environment humidity is 45%RH ± 5%RH) Indication range of oxygen concentration: 0%~99% Control range of oxygen concentration: 20%〜60% Accuracy of oxygen display concentration:± 2%(oxygen concentration sets ≦25%) ± 3%(oxygen concentration sets >25%) Accuracy of oxygen control concentration: ± 4% Weighing Range: 100-8000g(weighing system) Resolution for weight indication: 1g(weighing system) Accuracy of weigh:± 1 %(weighing system) |