Wondcon 610E Plus Infant Incubator
Wondcon 610E Plus
Accuracy and durability,Mindry quality,competitive price!
PRODUCT DETAILS
Introduction
Two control modes: Air mode and Baby mode controlled by micro-computer
Humidity display and control system
Oxygen concentration control system
Set temperature, Air temperature, Baby temperature, Humidity and Oxygen are displayed separately
“>37℃” temperature set function
Multiple failure alarm indications Embedded integrated sensor box
Integrated water reservoir in the shape of drawer
Double wall hood, automatic air circulation device
Inclination of bassinet is adjustable
RS-232 connector for data output
Low noise DC motor
Product Packaging
Package: Main body and Cabinet are packed into two cartons
Dimension (Main body): 1085mm x 640mm x 915mm
(Cabinet): 1125mm x 665mm x 730mm
Gross Weight (Main body): 68Kg
(Cabinet): 60Kg
Standard Configuration
Wondcon 610E:
Hood, Base, Mobile Cabinet, Controller, I.V pole, Tray;
Wondcon 610E Plus:
Based on Wondcon 610E, with Oxygen concentration control system.
Optional Configuration
Fixed Neonate Bilirubin Phototherapy Equipment model with blue fluorescent lamps;
Fixed Neonate Bilirubin Phototherapy Equipment model with blue LED;
Vertical height adjustment stand (VHA stand) Weighing system, Disposable skin temperature sensor and SpO2.
Environmental temperature
Operating range: 20 °C~30°C(Set temperature should be 3'C higher than the environment temperature) Ambient air velocity: <0.3m/s
Specification
Power supply: AC220V-230V/50Hz or AC110-120V/50-60HZ, 1000VA Control Mode: Air mode and Baby mode controlled by microcomputer Air temperature control range: 25°C-37°C(override mode37°C-39°c ) Baby temperature control range: 34°C-37°C (override mode 37°C-38°C) Accuracy of skin temperature sensor: ± 0.2°C The temperature fluctuation range between incubator temperature and average incubator temperature (under stable temperature condition): ≦O.5°C Temperature uniformity:≦0.8 °C (mattress is on the horizontal position) Inclination of the bassinet: ±12° (stepless adjustable) Noise inside hood: ≦45dB(A) Failure alarm: over-temperature alarm, temperature deviation alarm, sensor alarm, motor fan failed alarm, power failure alarm, water tank position alarm, system alarm and so on. Humidity display range: 0%RH〜99%RH Humidity control range: 0%RH〜90%RH Accuracy Of humidity display:± 5%RH(environment temperature is 25°C, environment humidity is 45%RH ± 5%RH) Indication range of oxygen concentration: 0%~99% Control range of oxygen concentration: 20%〜60% (for Wondcon 610E Plus) Accuracy of oxygen display concentration:± 2%(oxygen concentration sets ≦25%) ± 3%(oxygen concentration sets >25%) Accuracy of oxygen control concentration: ± 4% (for Wondcon 610E Plus ) |