Wondcon 610C Infant Incubator
Wondcon 610C
Accuracy and durability,Mindry quality,competitive price!
PRODUCT DETAILS
Introduction
Two control modes: Air mode and Baby mode servo controlled by micro-computer
The information can be stored, checked, and indicated by the color LCD display screen
Humidity and Oxygen concentration display and servo control system
“>37℃” temperature set function
The air circle with outlet in both front and back of the hood
Low noise brushless DC motor
Operating doors on three sides
X-ray cassette under the bassinet
Water reservoir integrated with heater, high temperature disinfection can be applied
Inclination of bassinet is adjustable
The height of whole unit can be adjusted
Multiple failure alarm indications
RS-232 connector for data output
Standard Configuration
Main body(including hood, base, controller, I.V.pole and Tray), the senor box, skin temperature sensor and vertical height adjustment stand (VHA stand)
Environmental temperature
Operating range: 20°C〜30°C(Set temperature should be 3°C higher than the environment temperature) Ambient air velocity: ≦0.3m/s
Optional Configuration
Weighing system, Disposable skin temperature sensor, Observation lamp.
Product Packaging
Package: The whole unit is packed into one carton. Size: 1230mm x 780mm x 1705mm Gross Weight: 190Kg
Specification
Power supply: AC220V-230V/50Hz or AC110-120V/50-60HZ, 1300VA Control Mode: Air mode and Baby mode controlled by microcomputer Air temperature control range: 25°C-37°C(override mode37°C-39°c ) Baby temperature control range: 34°C-37°C (override mode 37°C-38°C) Accuracy of skin temperature sensor: ± 0.2°C The temperature fluctuation range between incubator temperature and average incubator temperature (under stable temperature condition): ≦O.5°C Temperature uniformity:≦0.8 °C (mattress is on the horizontal position) ≦1.0°C(mattress is on the maximum tilt position) Inclination of the bassinet: ±12° (stepless adjustable) Noise inside hood: ≦45dB(A) Failure alarm: over-temperature alarm, temperature deviation alarm, sensor alarm, motor fan failed alarm, power failure alarm, water tank position alarm, system alarm and so on. Humidity display range: 0%RH〜99%RH Humidity control range: 0%RH〜90%RH Accuracy of humidity display: ± 5%RH Accuracy of humidity control: ± 5%RH Indication range of oxygen concentration: 0%〜99% Control range of oxygen concentration: 20%〜60% Indication accuracy of oxygen concentration:± 2% (oxygen concentration setting value is 25% and below) ± 3% (Oxygen concentration setting value is 25% and above) Control accuracy of oxygen concentration: ±4% Weighing Range: 0-8000g (weight system) Resolution for weight indication: 1g (weight system) Accuracy of weigh indication: ± 1% (weight system) |