Wondcon WME980H ETCO2 monitor
Wondcon WME980H
compact,stable and reliability portable Patient monitor.
PRODUCT DETAILS
Features
3.5 inch TFT monitoring the EtC02/C02, Respiration ratefSp02 and Putse (optional)
Wondcon's EtC02 mainstream technology of infrared ray gas analysis
Meticulously chosen narrow band optical filter,infrared source and delicately designed hardware electrical circuit and software algorithm ensure to realize high SNR (signal to noise ratio) gas concentration measurement and ensure the measurement accuracy in the range of 5-50*0 of temperature and within 0-20% of concentration,
Balance gas compensation makes minimum influence against other gases,
Pressure compensation makes high accuracy in different altitude,
Lung pressure and temperature compensation (BTPS compensation) is selectable,
Very short warmup time, inis seconds it can measure with complete accuratcy
Easy maintenance and no need to calibrate
KPA, mmHg or % are selectable.
Solid design challenges hush conditions and specially designed airway adapter is suitable for intubated adult or infant monitoring.
Audio-optical alarm for exceeding limits and Apnea
24 hours trend diagram keeps stilt available after power-off
Data output via USB port
Optional data base software administration analysis and printing data
Optional bluetooth module and bluetooth printer, at any time to print wave shape and data
Large Capacity lithium battery for 10 hours UPS
Nellcor or our Digital Sp02 and adult pediatric or neonate
The Analog Output Module is convenient to connect with to all kinds of multi-lead sleep monitors
Easy to connect and fix with anesthetic machine
Clinic significance of EtC02 monitoring
Adaptation diseases: 1. Safe application for anesthetic machines and ventilators. 2. insufficiency of alt kinds of respiration. 3. Cardio-pulmonary resuscitation. 4. Serious shock . 5. Cardiac failure and infarct. 6. Locating intubated catheter in general anesthetic trachea.
When ventilator and anesthesia are being applied, to use EtC02 measurement to adjust ventilating volume so as to keep EtC02 concentration level as same as that before operation. Monitoring EiC02 wave shape can determine if intubated catheter is in trachea. Referring patient using ventilator, if leaked, twisted or blocked of catheter happen, EtC02 wilt immediately alarm both audibly and optically and alert doctor to deal with. Continuous monitoring ensures safety remove ventilator and anesthetic machine. When malignant high barometric temperature, body temperature increasing and large injecting NaHC03 etc. can increase C02, EtC02. wave gain and meanwhile can lead to shock, cardiac arrest, pulmonary embolism and thrombus infarct, pulmonary blood flow decreasing can bring EtC02 concentration down to zero. EtC02 can help judge availability ofcardio- pulmonary resuscitation. Ultralow EtC02 needs to exclude the factors of overventilation etc. Besides.EtC02 curve is directviewing and shortcut, index both for pulmonary ventilation and circulatory function. EtC02 is oneof most important monitoring index for anesthetic and critically-ill patients.
Specification
Power | |
AC input: | 100V-250V, 50HZ/60 Hz |
AC power Consumption: | 10W |
Operation | |
Working temperature: | 5-50*C |
Humidity: | 30 -75% ( non-condensing) |
Atmospheric pressure: | 55-115kPa |
Battery Data | Lithium battery, rechargeable |
Battery capacity: | 3.6V,3800mAh! 15 hours (approximately) |
Charging time: | 4 hours from empty to full |
Physical Data | |
Dimension: | 72mm(W)x155mm(H) x28mm(D) |
Weight: | Mainstream sensor <90g. Monitor 250g |
Capnograph Measuring Data | |
EtC02/C02 | |
Range: | 0-150mmHg C 0-20kPa,or 0-20% <V/V)) |
Accuracy: | ±2mmHg when 0-40mmHg, ±5%(reading) when > 41-70mmHg ±8%(reading) when > 71-100mm Hg ±10%(reading) when > 101-150mmHg |
EtC02 Update: | every breath,I0sec,20sec or 30sec selectable |
Trend length: | 24hours |
Respiration rate | |
Range: | 3-150t/min |
Accuracy: | the bigger value of ±1%(reading) or ±1times/min |
Trend length: | 24 hours |
Flux: | 50-250cc/min selectable |
Oximeter Data (optional) | |
Oximetry Saturation | |
Range: | 0-100% |
Accuracy: | ±3% when 50-69% |
±2% when 70-100% | |
Trend length: | 24hours |
Pulse Rate | |
Range: | 30-250 bpm |
Accuracy: | the bigger value of ±2bpm or ±2%(reading) when 30-250bpm |
Trend length: | 24hours |