Medical Solution Supplier

Wondcon WME980D Patient monitor

Wondcon WME980D 

compact,stable and reliability portable Patient monitor. It is used for hospital,clinic,etc

Share:

PRODUCT DETAILS

Features

7” high resolution color TFT display 

Arrhythmia analysis and ST segment analysis 

Up to 12000 groups data record storage 

60-hour ECG waveform storage and recall 

1000-hour data trends for all parameters with graphic and list view 

2000 groups of event data storage 

2000 groups of arrhythmia events data with corresponding HR, TEMP, CO2, SpO2, and RESP value

Protection against defibrillator interference 

Adult / Infant measurement modes 

Visual and audible alarms

Product Accessories

Wondcon WME980D Patient monitor

Wondcon WME980D Patient monitor

NIBP
TechniqueOscillometric
Cuff pressure range0 mmHg ~ 300mmHg
Pressure precision±3mmHg
Cuff inflation time<10 seconds (typical adult cuff)
Overpressure protection

Adult/Pediatric 300mmHg

Neonate 140mmHg

BP measuring range

Systolic pressure

Adult 40mmH~255mmHg 

Pediatric 40mmHg~200mmHg

Mean arterial pressureAdult 20mmHg~215mmHg Pediatric 20mmHg~165mmHg
Diastolic pressureAdult 10mmHg-195mmHg Pediatric 10mmHg~150 mmHg
BP measuring accuracyMaximal mean difference ±5 mmHg
Maximal standard deviation8 mmHg
Measurement modeManual, Auto, STAT
TEMP
Measuring range25.0°C~45.0°C
Measuring accuracy±0.2°C
Responding timeW150s
Quick temp(optional)<20s(skin), <2s(ear)
SpO2
TransducerDual-wave length LED
SpO2 measuring range35%~100%
Low perfusion capability0.4%~5%
SpO2 measuring accuracyArms less than 3% for SpO2 range from 70% to 100%
Low perfusion performance0.4%
PR measuring range30bpm~240bpm
PR measuring accuracy±2bpm or ±2%, whichever is greater
ECG
Input dynamic range±0.4mVp~±5mVp
HR measuring range20bpm~300bpm
HR measuring accuracy±1 % or ±2bpm, whichever is greater
HR alarm delay timeW10s
Sensitivity selection*1/2, *1, *2, tolerance £5%
Sweeping speed12.5mm/s, 25mm/s, 50mm/s, tolerance M10%
ECG noise level^30|iVp-p
ECG input loop currentWO.IpA
Input impedance25MQ
Common-mode rejection ratioN89dB
Time constant20.3s (Monitoring mode)
Frequency response0.5Hz~40Hz (Monitoring mode)
RESP
RR measuring range0qjm~120rpm
RR measuring accuracy±5% or ±2 rpm, whichever is greater
Others
Power supply100~240VAC, 50/60Hz
Rechargeable Li-ion battery14.4V 2200mAh
Display7 inches TFT color LCD with 800x480
AlarmingAudible & visual alarm
CommunicationSerial/ Ethernet
Standard Configuration
ECG, RESP, SpO2, NIBP, TEMP, PR
Option
Nellcor SpO2, Trolley Wall Mount, Central monitoring system, External printer


SEND MESSAGE