Wondcon WME980B Patient monitor
Wondcon WME980B
Accuracy and durability,Mindry quality for OR,ICU,CCU use.
PRODUCT DETAILS
Features
12 inch high resolution touchable display for easy reading
Portable design and user-friendly interface for easy operation
Flexible configurations to meet different clinical needs
Optional IBP,ETCO2,CO,VGA,printer
Optional CMS function,up to 64 beds
Optional wifi/3G/4G moduleBuilt-in rechargeable Lithium-ion battery for fluid
Built-in rechargeable battery
7 hours continuous working with battery
12 months warranty
Standard configuration specification | |
Display | Pulse rate |
12.1” color TFT LCD touch Screen,resolution: 800 x 600 8 waveform display,12-leads ECG display | Range: 30~254 bpm Resolution: 1bpm Accuracy: ±3bpm (non-motion) ±5bpm (motion) Refreshing rate: 1s |
I/O | NIBP |
LAN: 1 standard RJ45 port WLAN: IEEE802.11b/g/n USB:2 USB connectors SD: 1 SD card socket Output:1 connector for nurse call,Defib sync analog output VGA: 1 color VGA monitor connector(optional) | Measurement method : Automatic oscillometric method Operating mode:Manual, automatic, continuous Measurement unit: mmHg/kPa selectable Typical measurement time: 20~40s Measurement type: Systolic, Diastolic,Mean Measurement range (mmHg) Range of Systolic pressure: Dog 40-270 Cat 40-200 Others 40-135 Range of Diastolic pressure: Dog 10-210 Cat 10-150 Others 10-95 Range of Mean pressure: Cat 20-230 Dog 20-165 Others 20-105 Measurement accuracy Maximum average error: ±5mmHg Maximum standard deviation: 8mmHg Resolution: 1mmHg Interval:1,2,3,4,5,10,15,30,60,90,120,180,240,48 0minutes Overpressure protection: Software and hardware,double safety protection Cuff pressure range: 0-280mmHg |
RESP | |
Method:Trans-thoracic impedance Operation modes: Auto/Manual Measurement range: Adult:0~150 bmp | |
TEMP | |
Accuracy: ±0.1℃ or ±0.2℃ °F (without probe) Measurement range: 5~50℃(41~122° F) Channel:Two channels Resolution: 0.1℃ Parameters:T1,T2 and TD | |
Pulse rate | |
Range: 30~254 bpm Resolution: 1bpm Accuracy: ±3bpm (non-motion) ±5bpm (motion) Refreshing rate: 1s | |
SPO2 | Operation environment |
Measurement range : 0-100% Resolution: 1% Accuracy: ±2%(70-100% Cat/Dog);± 3%(70-100%,Others); 0-69%,unspecified Refreshing Rate: 1s | Power: AC 100-250V, 50/60Hz Temperature: 5-40℃ Humidity: <85% |
Optional Configuration Specification | |
IBP Optional | Masimo IRMATM Mainstream CO2 (optional) |
Channel:2-channel or 4-channel ART: 0 to 300 mmHg PA: -6 to 120 mmHg CVP/RAP/LAP/ICP : -10 to 40 mmHg Measurement range: P1/P2 -50 to 300 mmHg Resolution:1mmHg Accuracy: ±2% or ±1mmHg, whichever is greater(without sensor) Sensitivity: 5uV/mmHg/V Impedance range: 300 to 3000Ω | Measurement Range: 0 -25% Warm-up time: Full accuracy within 10 seconds Accuracy: 0~15% (±0.2% of the reading) 15~25%, unspecified AWRR Range: 0-150bpm |
VGA/HDMI(Optional) | |
Connector to TV monitor | |
WIFI/3G/4G module | |
Connect internet | |
CMS system | |
At most up to 64 units | |
C.O. Optional | Recorder(optional) |
Method: Thermodilution Range: C.O.: 0.2 to 20 L/min TB: 23 to 45 ℃ T1: -1 to 27℃ Accuracy:C.O.:±5% or ±0.1L/min, whichever is greater TB,T1:±0.5℃ (without sensor) | Built-in,Thermal dot array Horizontal resolution :16 dots/mm (25 mm/s paper speed) Vertical resolution:8 dots/mm Paper speed:25 mm/s, 50 mm/s Number of waveform channels:3ptional) |
Main unit with SPO2,NIBP,ECG,T1/T2 port
Accessories
Reusable adult cuff | |
Adult SPO2 line | |
Temperature Line 2pcs | |
ECG line |
Stand or wall type for choose
Thermal printer | |
IBP | |
ETCO2 | |
Wifi/3G/4G module | |
CO |
Noted: Before order,please tell which optional function do you need,thanks!