Wondcon WME 980A Patient monitor
Wondcon WME 980A
Accuracy and durability,Mindry quality,competitive price!
PRODUCT DETAILS
Features
8 inch high resolution display for easy reading
Lightweight,portable design and user-friendly interface for easy operation
Flexible configurations to meet different clinical needs Built-in rechargeable Lithium-ion battery for fluid
Built-in rechargeable battery5 hours continuous working
12 months warranty
Standard configuration: SPO2+NIBP+PR+ECG+RESP+Temp
Main unit with SPO2,NIBP,ECG,T1 port
Reusable Adult cuffAdult SPO2 line Temperature line ECG line
Optional configuration
Stand or wall type
Specification
Display | NIBP |
8” color TFT LCD touchable Screen,resolution: 600 x 800 | Measurement method : Automatic oscillometric method Operating mode:Manual, automatic, continuous Measurement unit: mmHg/kPa selectable Typical measurement time: 20~40s Measurement type: Systolic, Diastolic,Mean Measurement range (mmHg) Range of Systolic pressure: Dog 40-270 Cat 40-200 Others 40-135 Range of Diastolic pressure: Dog 10-210 Cat 10-150 Others 10-95 Range of Mean pressure: Dog 20-230 Cat 20-165 Others 20-105 Measurement accuracy Maximum average error: ±5mmHg Maximum standard deviation: 8mmHg Resolution: 1mmHg Interval:1,2,3,4,5,10,15,30,60,90,120,180,240,480minutes Overpressure protection: Software and hardware,double safety protection Cuff pressure range: 0-280mmHg |
ECG | |
Lead type 3-lead:I, II, III 5-lead:I, II, III,aVR, aVL, aVF, V Display sensitivity: 2.5mm/mV (×0.25), 5mm/mV (×0.5), 10mm/mV (×1.0), 20mm/mV (×2.0) Wave sweep speed: 6.25mm/s, 12.5 mm/s, 25 mm/s, 50 mm/s Bandwidth Diagnostic mode: 0.05Hz~100Hz Monitor mode: 0.5Hz~40Hz Surgery mode: 1Hz~20Hz Strong filter mode: 5Hz~20Hz CMRR>100dB Notch: 50/60Hz notch filter can be set to on or off Differential input impedance>5MΩ Electrode polarization voltage range: ±400mV Baseline recovery time<3s after defibrillation (in monitor and surgery mode) Calibration signal:1mV (peak - peak), accuracy ±3% | |
RESP | SPO2 |
Measurement method : Thoracic electrical bioimpedance Measuring lead: Lead I, II Wave gain: ×0.25, ×0.5, ×1, ×2 Respiratory impedance range: 0.5-5ΩBaseline impedance: 500-4000Ω Gain: 10 grades Scan speed: 6.25mm/s, 12.5 mm/s, 25mm/s | Measurement range : 0-100% Resolution: 1% Accuracy: ±2%(70-100%, Cat/Dog); ±3%(70-100%); 0-69%,unspecified Refreshing Rate: 1s |
TEMP | Pulse rate |
Measurement method: Thermistor Measuring range: 5~50°C (41~122°F) Resolution: 0.1°C Measurement accuracy: ±0.1°C | Range: 30~254 bpm Resolution: 1bpm Accuracy: ±2bpm (non-motion) ±5bpm (motion) Refreshing rate: 1s |
Operation environment | |
Power: AC 100-250V, 50/60Hz Temperature: 5-40℃ Humidity: <85% |