Wondcon WME910E Emergency portable ventilator
Wondcon WME910E
Accuracy and durability,Mindry quality,competitive price!
PRODUCT DETAILS
Ventilation Mode
Typical ventilation mode with BIVENT and PRVC, fully meet the demands of critical care mechanical ventilation |
Monitoring
Waveforms and loops display with powerful monitoring function gathers comprehensive patient information |
Comprehensive Monitoring Function
Complete manual interventions include inspiratory and expiratory hold, manual ventilation, synchronized nebulizer and smart suction |
Information Gathering Function
VT5230 can be updated through Internet or USB ports Efficient transport of patient information meets the need of digital hospital |
15" TFT Touch Screen With Navigation Wheel
With a 15" TFT touch screen and a simple intuitive interface, the user can easily complete the entire operation |
Guide-way Operation
Guide-way operation function boots the operation efficiency and patient safety |
Advanced Pneumatic System
The unique Ventank pneumatic system ensures the accuracy of oxygen and gas delivery |
Metal made autocalvable exhalation valve with built-in flow sensor fulfills the needs of low maintenance cost |
•Provide proper mechanical ventilation support with lung protective ventilation strategies
•ATC reduces the resistance caused by either endotracheal tube or tracheostomy tube, lowers patient work of breathing
•Bivent mode provides two levels of continuous positive airway pressure(CPAP) with pressure support breaths, suitable for more types of patient
Non-invasive Ventilation
•Proper use of NIV decrease the need for intubation reduces the patient weaning time
•VT5230 includes NIV ventilation as a standard feature. Users have the flexibility to use V5230 for both invasive and non-invasive therapy to reduce equipment costs
Monitoring
• 3 waveforms and 3 loops
• Alarm/Event records description of each alarm and provides information of any changes of settings. Trend function provides 72h of full patient data. Convenient for information search and shift management
Lung Mechanics
•Measures static compliance, air resistance, PEEPi, P0.1 and time constant to help the doctor evaluate treatment outcome
Thoughtful Configure Solution
•Depending on ICU environment, VT5230 can be equipped with air compressor on mobile cart and ceiling pendant
•The design of integrated power supply solution with circuit breaker provides more protection of the ventilator, air compressor and humidifier
Technical Specification
Ventilator Function |
•Modes VCV (A/C), PCV (A/C), PRVC (A/C), SIMV (VCV/PCV/PRVC) + PSV, SPONT/CPAP + PSV, BIVENT/APRV + PSV Non-invasive ventilation:NIV/CPAP+PSV, NIV/PCV •Tidal Volume 20-2500 ml •Respiratory Rate 1-120/min •Inspiration Time 0.2-9 s •Inspiratory Pause Time 0-4 s •Tslope 0-2 s •Thigh 0.2-30 s •Tlow 0.2-30 s •FiO2 21%-100% •PEEP 0-50 cmH2O •Psupport 0-90cmH2O •Pcontrol 5-90cmH2O •Esens 5%-80% •Inspiratory holdYes •Expiratory hold Yes •Manual inspiration Yes •Waveform freeze Yes •Nebulizer 30 or 45 min. •Suction Maximum 3 min. |
Monitoring |
•Pressure values Pmin, Pplat, Pmean, Ppeak, PEEP •Volume / flow values VTi, VTe, MV, MVspont, Leak% •Time values ftotal, fspont, I:E, Tc, Tispont •Oxygen monitoring O2 sensor •Weaning parameters dynamic and static compliance, resistance, PEEPi, P0.1, RSBI, WOB |
Alarm |
MV: High/low; Vti: High; Airway pressure: High/low; Continuous airway pressure: High; PEEP: High/low; fspont: High; FiO2: High/low; EtCO2: High/low; Tapnea |
Technical Data |
•Screen 15" TFT color touch screen (detachable) •Dimension 575X370X470 mm •Weight 30kg •Gas supply O2, Air, 200kPa-650kPa (29-94 PSI) •Power supply 100 – 240V, 50 – 60 Hz •Back-up batteryBuilt-in battery, optional 2nd internal battery •Communication interfaces USB*2, RJ45*1, RS232*1, real-time VGA output •Temperature 10 – 40℃ (Operation) -20-60℃ (Storage) |
Standard configuration
Name | Qty |
Ventilator Main Unit | 1 |
Valve diaphragm | 2 |
Water Trap | 1 |
O-shaped rubber ring 4x1.8 | 1 |
Cover | 1 |
One-way diaphragm | 1 |
Hexagon socket head cap screws M5X12 | 1 |
Fan filter | 2 |
Fuse T2AH250V | 2 |
Fuse T4AH250V | 1 |
Nebulizer | 1 |
800-51900-11 Bacterial filter | 2 |
Power cable | 1 |
Ventilator User Manual | 1 |
Adult breathing circuit kit | 1 |
Face mask | 1 |
Head band | 1 |
800-21001 Adult artificial lung | 1 |
Oxygen inlet filter | 1 |
Oxygen pipe line | 1 |
Oxygen sensor | 1 |
Standard Battery Components | 1 |
VHB10A Humidifier | 1 |
Arm | 1 |
lead-acid battery pack | 1 |
Air pipe line | 1 |
Expiratory valve core component | 2 |
Attached file list
Name | Qty |
Qualified certificate | 1 |
Packing list | 1 |
Standard configuration
Name | Qty |
Trolley without compressor | 1 |
IEC Power Cable (900mm) | 1 |
Air pipe line | 1 |
Z type assembly without air compressor | 1 |
6300 baffle | 1 |
Pediatric breathing circuit kit | 1 |
Baby breathing circuit kit | 1 |
G-118000-0 Newborn Artificial Lung | 1 |
Humidifier connect block | 1 |
Adult breathing Hoses | 1 |
Child breathing Hoses | 1 |
Bacteria Filters (BSF103) | 1 |
Expiratory Valve Core Component | 1 |
service manual | 1 |
IRMA_CO2 gas module | 1 |
IRMA adult adapter | 1 |
IRMA infant adapter | 1 |