Medical Solution Supplier

Wondcon WME910D Emergency portable ventilator

Wondcon WME910D

Accuracy and durability,Mindry quality,competitive price!

Share:

PRODUCT DETAILS

Superior Mobile ICU ventilator

•Comprehensive ICU ventilator including BIVENT and PRVC 

•Compact, big capacity battery, no air compressor, intra-hospital mobility 

•Flexible device configuration: equipped on a trolley, bed or ceiling pendant

Cost Effective Solution

• Unique metal-based, autoclavable, heated exhalation valve 

• Built-in flow sensor, non-consumable design 

• Upgradeable ventilation system software, with an available USB port

Optimal patient-ventilator synchrony, increase patient comfort

• The Unique Leak Compensation System - Keep precise control on the tidal volume of each breath delivered to the patient by adjusting compensation dosage automatically 

• Advanced Trigger Technique - Enhance sensitivity, avoid spurious triggering

Auto-detect and Adjust LeakAutomatically Adapt to Patient’s Breathing PatternMulti-parameter Monitoring
Safe Ventilation Through Whole Treatment Phase

Initial Treatment Phase 

• Noninvasive ventilation mode associated with decreased intubation rates, shortened patient stays, improved patient comfort, and a reduced risk of cross infection 

•Preset patient’s height and IBW. Reduce clinician’s workload 

Stable Condition Phase 

• PRVC and BIVENT employ lung-protective strategies, delivering intelligent ventilation 

•Comprehensive lung mechanics monitoring include compliance, airway resistance, PEEPi and time constant 

• Three waveforms & three loops with user-friendly display provide a continuous monitoring of the patient’s condition 

Weaning Phase 

•Various ventilation modes enhance the weaning process 

•The unique trigger and leakage compensation system safeguards each and every patient breath resulting in smooth and comfortable breathing, avoiding extra workload on the patient and promoting recovery 

•RSBI and WOB provide accurate reference for weaning 

Rehab Phase 

•Data export port provides connection to hospital monitors and Patient Data Management Systems

Optional configuration

NameQtyNameQty
Arm1Internal battery RRC20241
6300 baffle1Gas cylinder mounting component1
Humidifier connect block1Paramagnetic oxygen sensor stripling assembly1
Pediatric breathing circuit kit1The quick sonnector1
Newborn breathing circuit kit1IRMA_CO2 gas module1
G-118000-0 newborn artificial Lung1IRMA adult adapter1
Bacteria Filters (BSF103)1IRMA infant adapter1
Adult breathing circuit1W0001 cable1
Child breathing circuit1Exhalation valve core assembly1
Product pictures

Wondcon WME910D Emergency portable ventilatorWondcon WME910D Emergency portable ventilator

Ventilation Settings

Ventilation Modes

•VCV (A/C), PCV (A/C), PRVC (optional), PSV (optional), STANDBY 

•SIMV (VCV)+PSV, SIMV (PCV)+PSV, SIMV (PRVC)+PSV 

•SPONT/CPAP+PSV 

•BIVENT/APRV +PSV (optional) 

•NIV/CPAP, NIV-T, NIV-S/T

Enhancements

•Apnea ventilation, Pressure and Flow trigger, Automatic Tube Compensation (ATC), Smart suction 

•Manual breath, Insp/Exphold, Screen freeze, Nebulization, Lung recruitment

Parameters

•Tidal volume (VT) 20-2000ml 

•Respiratory rate (RR) 1 to 80 bpm 

•Inspiratory time (Ti) 0.2 to 9 s (adult), 0.2 to 5 s (pediatric) 

•Inspiratory flow (Flow) 0 to 100 L/min (pediatric), 0 to 180L/min (adult) 

•Inspiratory pressure (Pinsp)5 to 70 mbar (or cmH2O) 

•Inspiratory pressure limit (Pmax) 80 mbar (or cmH2O) 

•PEEP 0 to 35 mbar (or cmH2O) 

•Tslope 0 to 2 s 

•O2 concentration (FiO2) 21 to 100 Vol% 

•Trigger sensitivity 0.5 to 20 L/min (Flow trigger),-20 to 0 mbar (or cmH2O) (Pressure trigger) 

•I/E ratio 1/10 to 4/1 

•Apnea alarm time 10-60 seconds

Monitoring

•Pressure values Pplat, Ppeak, Pmean, Pmin, PEEP 

•Volume/Flow values VTI, VTE, MV, MVe, MVspont 

•Time values ftotal, fspont, I:E 

•Inspiratory O2 concentration (FiO2), End-expiratory CO2 concentration (etCO2) 

•Compliance (dynamic & static), Resistance (R), MVleak, RSBI, WOB, I:E, Vdaw, PEEPi 

•Pressure-Volume loop, Pressure-Flow loop, Flow-Volume loop

Alarms

Expiratory minute volume (MV) High/Low, Airway pressure (Paw) High/Low, VTe Low, PEEP High/Low, Insp. O2 concentration (FiO2) High/Low, 

End-expiratory CO2 concentration (etCO2) High/Low, fspont High, Apnea alarm, Disconnection, Flow sensor error, Gas supply, 

Electrical supply & battery failure, Exhalation obstruction, Apnea backup for low frequency alarm

Physical Specifications

•Dimensions (WxDxH) 375mm x 395mm x 430mm 

•Weight 15kg (33.1lbs) 

•Screen 12.1" TFT color touch screen

Standard configuration

NameQty
Ventilator Main Unit1
Power cable1
Valve diaphragm2
Water Trap1
Cover1
One-way diaphragm1
Fan filter1
Filter Core1
Filter1
Nebulizer1
Internal battery RRC20241
Oxygen sensor1
Fuse T3.15AH250V2
Adult breathing circuit kit1
800-21001 Adult artificial lung1
Face mask1
800-51900-11 Bacterial filter2
Oxygen inlet filter1
Oxygen pipe line1
End cover1
VHB10A Humidifier1
Trolley component(220V)1
Arm1
user manual1
Attached file list

NameQty
Qualified certificate1
Packing list1









SEND MESSAGE