Wondcon WME900F Anesthesia Machine
Wondcon WME900F
compact,stable and reliability portable anesthesia machine.
PRODUCT DETAILS
Features
The comprehensive ventilation modes including PCV-VG,SIMV-PC provide more flexibility to ventilation strategy, suitable for various patients operation including pediatric and adult
Advanced ventilation management, provides a accurate and broad of settings enabling effective care across a wide range of patient sizes and acuity types
Support both low-flow anesthesia and mini-flow anesthesia
Compact breathing system, easy to remove and clean, fully autoclavable, optional CO2 bypass
Electronic flow-meter, precise control and convenient operation
12.1’’ TFT LCD with color touch screen, highlighted display
Optional comprehensive gas monitoring include: oxygen (paramagnetic), CO2, AG, etc.
CE marked, meets EU clinical requirement
Product pictures
Technical Specifications
BASE UNIT |
Dimensions (H x W x D): Trolley version (with breathing circuit) 1403mm×704mm×750mm or 55.2in×27.7in×29.5in Weight and load: Trolley (without vaporizer and backup cylinder) 100kg or 220.5 lb Top shelf load 25kg or 55 lb Power and battery backup: Power input 100~240 VAC, 50/60 Hz Batteries and Operation time with fully charged DC24V, 4.0AH, Min.120minutes Environmental requirement: Operation temperature 10~+40℃ or 50~104℉ Operation humidity ≤80% (non-condensing) Storage temperature -20~+60℃ or -4~131℉ Storage humidity ≤95%(non-condensing) |
ANESTHESIA GAS SUPPLY MODULE |
Gas supply O2, N2O, AIR; 280kPa - 600kPa Cylinder yokes Optional: O2, N2O, AIR Fresh gas flow indicator Electronically display and virtual fresh gas flow tubes Range of fresh gas flow indicators O2, N2O (0.05~10.0 l/min), AIR (0.05~12.0 l/min) O2 flush 25~75 l/min Vaporizer Auxiliary common gas outlet (ACGO) Optional Anesthetic Gas Scavenging System (AGSS) Optional Agent Halothane, Enflurane, Isoflurane , Sevoflurane Installation mode Selectatec® with interlock, optional standby vaporizer parking holder Filling type Pour Fill, Key Fill, Quik-Fil Breathing system Volume of CO2 absorber 3 L for double-canister or 1.8 L for optional single canister |
VENTILATOR OPERATING SPECIFICATIONS |
APL Range Spontaneous breathing (SP) -70cm H2O Material Autoclavable (except O2 cell and mechanical pressure gauge) Heating system 32-40℃ CO2 bypass Optional Ventilator Electronically controlled, pneumatically driven Ventilation modes Manual/spontaneous Volume control (IPPV) Pressure control (PCV) Pressure Controlled Ventilation Volume Guaranteed (PCV-VG) Synchronized Intermittent Mandatory Ventilation in volume(SIMV-VC) Synchronized Intermittent Mandatory Ventilation in pressure(SIMV-PC) Pressure support (PS) with Apnea backup |
Control input ranges Breathing frequency (rate) 2~100bpm Positive end expiratory pressure (PEEP) OFF, 3~30cm H2O Inspiration/expiration ratio (Ti:Te) 4:1~1:8 Tidal volume (Vt) 20~1,500ml in volume control Inspiration pause OFF, 5%~60% Inspiratory time 0.2~5.0 s Inspiratory pressure (PTARGET) 5~70cm H2O Pressure support level (ΔP) 3~50cm H2O Pressure limit (Pmax) 10~70 cm H2O Trigger level 1~15 l/min Inspiratory Slope Time (TSLOPE) 0~2s Compensation Compliance and Leak compensation, fresh gas compensation, altitude compensation Ventilator monitoring & alarm Monitoring Continuous monitoring of inspiratory O2 concentration, breathing frequency, tidal volume, minute volume, peak airway pressure, PEEP, mean or plateau pressure, CO2 concentration (optional), anesthetic gas concentration (optional) paramagnetic oxygen sensors (optional) Compliance 0~100 mL/cm H2O Control screen 12.1 in; TFT color touch screen Graph Display Waveform of P-t, F-t, V-t, CO2-t (option), Paw-V Loop, V-Flow Loop Alarm MV high/low limit, FiO2 high/low limit, Paw high/low limit, Power failure Breath Rate high limit Subatmospheric pressure Sustained airway pressure Apnea alarm, Alarm Silence(120s) |
Optional configuration
Description | Spec. | Units |
Adult Breathing Circuit | —— | PCS |
PVC Anesthesia Loop | —— | PCS |
Pediatric Anesthesia Loop | —— | PCS |
PVCPediatric Anesthesia Loop | —— | PCS |
Bain Adult Breathing Circuit | —— | PCS |
Bain Pediatric Breathing Circuit | —— | PCS |
Jackson Rees Adult Breathing Circuit | —— | PCS |
Jackson Rees Pediatric Breathing Circuit | —— | PCS |
CO2 gas modular | —— | PCS |
Attached file list
Name | Qty |
Anesthetic MachineUser Manual | 1 |
PRODUCT QUALIFIED CERTIFICATE | 1 |
Packing List | 1 |
Operation Card | 1 |
Standard configuration
Name | Reference Figure | Name | Reference Figure |
Anesthetic Machine | —— | Fuse,T2A, 250V | |
Breathing System | Fuse,F10A, 250V | ||
O2 Pipeline (NIST) | FiO2 measurement | ||
N2O Pipeline(NIST) | Heater Cable | ||
Air Pipeline(NIST) | Tank Wrench | ||
Drive Gas Hose φ17 | O-shaped rubber seal ring 14×2.65 | ||
Ground wire | O-shaped rubber seal ring 18X1.8 | ||
Adult Breathing Circuit | O-shaped rubber seal ring 9×1.8 | ||
Machine Cover | |||
Hoop | |||
Drawer Lock key | |||
Breathing System Pneumatics | |||
DiscCeramic I/E Valve |